Where the inspection belongs in a remodel
Some remodels only change the wall. Others change the fireplace itself: wood becomes gas, a liner goes in, an insert replaces an open fire. That second kind is the point where a camera inspection of the whole chimney belongs, before the design is settled and well before the finish goes up.
This is how Farnham Chimney Sweep decides which inspection a Los Angeles remodel needs, what each costs, and what you can pass to your designer afterward.
The change that calls for the camera
NFPA 211, the fire code covering chimneys and fireplaces, describes inspections at three depths and names the occasions each one suits. For a remodel the useful part is short: when the venting system itself is changing, the deeper inspection is the one that applies. In practice that means:
- Switching fuel, for example wood to gas.
- Setting an insert or a stove into the fireplace.
- Relining the flue, or swapping one liner for another.
When the remodel is surface only, with new tile or a new mantel and the fireplace used exactly as before, the lighter check is usually enough.
There is one more case. If the house is one you are in the middle of buying, the code already counts the change of owner as a reason for the deeper look, so a single camera inspection can serve the purchase and your remodel plans at once. Our home sale inspection page covers that side.
What each level looks at
Level 1, $52. The open-view check. We work the damper, look over the firebox brick and its joints, check the hearth in front of it, and look at the stack and its top where it is safe to reach. Nothing is opened up and no camera goes in.
Level 2, $370. Everything in Level 1, plus a video camera inside the flue from the smoke chamber to the cap, so the report can show each section of tile and the joints between them. We also check the spaces the chimney passes through, such as the attic, for scorching and for how close the framing sits to the brick.
Level 3. This one involves taking out part of the structure to reach a hidden problem. A remodel sometimes does that work anyway, because the old face comes off. When it does, we look at what is exposed before the new face covers it again, which is a good habit on any refacing job.
What the report gives your designer
A remodel is easier to draw when it starts from facts. Along with the inspection findings, we take the measurements a remodel needs on the same visit:
- Width, height and depth of the firebox opening.
- Flue size and material, which decide the liner an insert would need.
- The condition of each length of flue, with frames from the camera.
- The present distance from the opening to the mantel and trim, and from the opening to the front edge of the hearth.
- Any repair needed before or during the remodel, in order of importance.
With that, a designer can size an insert, place a mantel and draw a hearth without guessing.
What decides the cost of the inspection step
The two inspections carry fixed prices, $52 and $370. What varies is how much the visit has to cover. Each extra flue in the stack goes on the report as its own section, and a second fireplace elsewhere in the house is a second inspection. A tall stack on a steep clay tile roof takes longer to reach safely, but the price stays the published one.
Tell us what the remodel will change, whether wood to gas, a new insert or a new face only, and we will say on the call which inspection the plan needs before booking it.
When the camera changes the design
Most of the time the camera simply confirms the plan. Sometimes it changes it.
A clay flue with a split tile partway up cannot safely carry an open wood fire, yet it can still house a stainless liner for an insert. The design holds; the budget gains a liner. Our post on whether an insert needs a new liner explains that work.
A smoke chamber with rough, stepped brick may need a smooth coat before an insert or a wood fire goes back in. A damper frame rusted into the throat can block the room an insert's venting needs, and taking it out goes on the scope.
And on houses in this part of the county, the 1987 Whittier Narrows shaking and the 1994 quake left some stacks rebuilt above the roof in a different brick, or not rebuilt at all. The camera shows where old work meets new, and whether that seam is sound.
Why the order matters
An inspection booked after the tile is set can only report on what it finds. Booked first, it shapes the plan. The flue size decides the insert, the insert decides the opening, and the opening decides the proportions of the whole face. Starting with the camera keeps the finish you choose from being cut out later.
It also keeps the trades in a sensible line. The chimney repairs go first, while the old face is still on and dust does not matter. The insert and its venting follow. The finish crew arrives last, to a wall that will not need opening again. On a Los Angeles remodel with a designer, a tile setter and a gas fitter all booked, that order saves everyone a return trip.
Book the inspection first
The contact page is the quickest way to start. Give us the address in Los Angeles or nearby and a sentence on what the new fireplace should be, and we will match the inspection to the plan. Our Level 2 inspection page has more on that visit.
Turn the Plan Into a Drawing
Farnham measures the wall and opening, checks the firebox and flue, and brings samples of stone, tile and plaster to the house. Our crews work out of Los Angeles and cover Bell, Downey, El Monte and the cities listed on the areas page.