Professional chimney service
Farnham

Pellet Stove Repair for the Stove That Warms the Room

Ask About Pellet Stove Repair

Itemized Estimate Up Front
Flue Photos in Each Report
Measured Drawings for Remodels
Clearances Checked to Code
Based in Los Angeles
Itemized Estimate Up Front
Flue Photos in Each Report
Measured Drawings for Remodels
Clearances Checked to Code
Based in Los Angeles

Scope of the Work

A pellet stove is a small machine around a firebox. When one stops feeding, fails to light or switches itself off, the fault is usually a motor, an igniter, a fan or a sensor. We test each part, replace what has failed with the maker's part where we can get it, clean the exhaust path and heat exchanger, and run a full burn before we leave. The finished room around it stays tidy.

Auger motors and feed jams cleared or replaced
Igniters replaced on the common makes
Room and exhaust fans cleaned and tested
Control boards and sensors diagnosed
Exhaust vent and heat exchanger cleaned
Full test burn before we pack up

How pellet stoves fail

Pellet stoves are clever heaters with a lot of moving parts, and most faults trace back to fuel, air or electrics. Fuel faults come first: pellets that bridge in the bin and stop flowing, a feed screw jammed by a long pellet or a bit of debris, a feed motor that has worn out after several seasons. Air faults come next: an exhaust path choked with fine ash, a door gasket that has gone flat so the stove pulls air from the wrong place, or a vent outside blocked by a nest. Electrical faults round it out: an igniter that no longer gets hot enough, a sensor that reads wrong and shuts the stove down, or a control board damaged by a power surge. Many owners first notice a stove that starts, runs a short while and then stops, or a fire that smolders and fills the glass with soot. We begin with the symptom, read any code on the control panel, and test along that path until we find the part that failed.

Cleaning is part of almost every repair. Fine ash collects in places the owner cannot reach, and a stove choked with it will act up even with new parts. We open up the stove, clear the ash from the burn area and the internal passages, vacuum the fans, and brush the exhaust vent from the stove to the outside cap. Then we check each part we can: the feed, the igniter, the fans and the sensors. Where a part has failed, we replace it with one made for that stove, and we test the stove through a full start and burn before we leave. Where the maker has stopped producing a part, you hear that up front, and we look for a fitting alternative before suggesting a new stove. You get a short written note of the fault, the repair and anything we saw that is close to wearing out.

The stove as part of the room

A pellet stove is a piece of furniture as well as a heater, and its setting matters. The hearth pad under it should be the right size for the stove and made of a material that suits the floor, such as slate, porcelain tile or a steel plate with a finished edge. The vent pipe should run neatly, either straight out through the wall or up into a lined chimney, with a finish that matches the stove rather than bare galvanized pipe. Clearances to walls, trim and furniture should follow the maker's instructions. When we repair a stove, we look at the whole setting, and where a pad is cracked, a pipe is dented or a wall behind the stove is scorched, we note it with a suggested fix. Small details change how a stove corner reads. A pad that is a few inches too narrow looks like an afterthought, and a pipe that jogs sideways on its way to the wall draws the eye away from the flame. A stove set square to the room, on a pad with a clean edge and a straight, matched pipe, looks deliberate, and it is usually safer too.

Pellet stove faults do not come with a menu price, since one stove needs a ten minute clean and the next a new feed motor. Before we start, you receive the figure in writing, covering the parts, the cleaning and the labor, and if we find a second fault partway through, we stop and tell you before going further. Pellet stoves that run all winter benefit from a cleaning and check each fall, which we can book at the end of the repair visit. If you are tired of the look of the stove or the area around it, a new hearth pad, a tiled wall behind it or a different vent route can change the corner completely. Our remodel work covers those changes, and they can be planned at the same time as the repair, so the stove ends up both working and looking right.

Working With Farnham Chimney Sweep

Measured First

Opening, hearth and flue recorded before any price

Room Protected

Floors and furniture sheeted while we work

Line-Item Estimate

Face, hearth, mantel and repairs priced apart

Photos Included

Before and after pictures with the paperwork

Related Work We Do

Chimney Sweep

Soot and creosote lifted out of the flue so a refinished fireplace burns clean and its new face stays unmarked.

Read more

Chimney Inspection

A look at the whole chimney before a remodel, a sale or a new appliance, recorded in photos and plain notes.

Read more

Chimney Repair

Brick, mortar, crown and flue repairs that keep the stack sound behind the fireplace you are planning to refresh.

Read more

Fireplace Inspection

Firebox, damper, hearth and surround checked for safety and measured for the remodel you have in mind.

Read more

Fireplace Repair

Cracked firebrick, a grinding damper, a loose hearth or a stained face repaired so the fireplace can stay and look right.

Read more

Chimney Level 2 Inspection

Camera footage of the flue plus attic and roof checks, the record a buyer, lender or insert installer usually wants.

Read more

Chimney Cap Installation

A metal hood picked to suit the roofline and fixed over the flue so weather and animals stay out.

Read more

Chimney Flashing Repair

New step and counter flashing where the stack meets the roof, finished neatly so it reads as part of the roofline.

Read more

Chimney Masonry Repair

Brick and mortar on the stack repaired in matched color and joint shape, so the patch disappears into the old work.

Read more

Chimney Rebuilds

A failing stack taken down and rebuilt in brick that suits the house, with a new crown, flashing and cap.

Read more

Fireplace Cleaning

Firebox, glass doors and the brick or stone face cleaned so the fireplace looks cared for again.

Read more

Gas Fireplace Cleaning

Burner, logs, glass and pilot cleaned on a gas unit so the flame looks even and the window stays clear.

Read more

Gas Fireplace Repair

Pilots, igniters, valves, remotes and burners repaired so a gas fireplace lights when asked and looks right.

Read more

Fireplace Remodel

A dated fireplace redrawn for the room: a new face, a mantel in proportion to the wall and a hearth that meets code.

Read more

Fireplace Inserts

A sealed gas or wood insert set into the old opening, with a liner and trim that suit the new face.

Read more

Wood Stove Repair

Door seals, glass, baffles, firebrick and pipe on a wood stove renewed so it burns cleanly and looks cared for.

Read more

Gas Logs

A gas log set chosen for how it looks in the firebox, fitted with its own valve and tested before we leave.

Read more

Chimney Seismic Retrofit

Older brick stacks secured, or rebuilt lighter above the roof, so a strong quake is less likely to bring them down.

Read more

Chimney Crown Repair

The masonry top of the stack sealed or recast with a proper fall and overhang.

Read more

Dryer Vent Cleaning

Lint cleared from the duct between the dryer and the outside hood, with airflow measured at the end.

Read more

Chimney Liner Installation

A stainless liner run the height of the flue for an insert, a new stove or a clay flue that has cracked.

Read more

Chimney Leak Repair

Water at the chimney traced to the part letting it in, then that part repaired before any finish is redone.

Read more

Chimney Waterproofing

A breathable repellent applied to sound brick so rain beads off and the masonry above the roof stays drier.

Read more

Chimney Damper Repair

Dampers that stick, rattle or fail to close repaired, or replaced with a gasket-sealed top damper.

Read more

Chimney Chase Cover

Rusted or sagging metal tops on framed chimneys replaced with a made-to-measure cover that sheds water.

Read more
Call (323) 524-3663